EKCO.MN3 & M3
A boiler with weather compensation control capable of interacting with the central heating system and the hot-water heat exchanger, equipped with a circulating pump and a 5L diaphragm expansion vessel (EKCO.MN3)
In a nutshell
- electric boiler with weather compensation control
- wide power range from 2kW to 24kW
- built-in circulating pump
- interaction with any central heating system and hot-water heat cylinder
Adapt to the weather
Thanks to the weather compensation controller, the boiler is even more comfortable to use, as well as energy-saving. The weather sensor reacts quickly to the changing temperature outside and harmoniously adjusts the central heating system – which ensures smooth operation of the boiler.
Get warm exactly when you need it
Does it make economic sense to maintain a comfortable temperature in the building when no one is at home? No. That is why setting the daily and weekly cycle allows you to adjust the boiler operation to your lifestyle. Thanks to this solution, the temperature is comfortable and heating expenses are significantly reduced.
Several power ranges in one device? It is up to you to choose the boiler power appropriate for your home.
Thanks to the possibility of changing the power, it will not be necessary to replace the boiler after changing the parameters of your house’s heating demand (for example, after thermal efficiency improvement). With this option, you can adjust the power of your boiler for the heating to be best suited to your needs.
Easy and convenient control of the boiler’s operation
With a clear and legible LCD display and an intuitive menu, the boiler’s parameters are set comfortably. Contrasting graphics and quick operation of the controller increase the precision of setting the boiler.
Product code | EKCO.MN3-04/06/08 | EKCO.MN3-12/16/20/24 | EKCO.M3-04/06/08 | EKCO.M3-12/16/20/24 |
---|---|---|---|---|
Energy efficiency class | D | D | D | D |
Heat capacity | 2/4/6/8 kW | 12/16/20/24 kW | 2/4/6/8 kW | 12/16/20/24 kW |
Power supply | 400V 3N~ lub 230V~ | 400V 3N~ | 400V 3N~ lub 230V~ | 400V 3N~ |
Dimensions L x W x H (mm) |
316 x 235 x 716 | 316 x 235 x 716 | 316 x 191 x 716 | 316 x 191 x 716 |
Weather compensation control optional equipment |
||||
Possibility to connect a second heat source |
||||
Expansion vessel |
Product code | Description |
SENSOR WE-019/01 | A water temperature sensor in the hot-water heat exchanger or temperature sensor in the additional heating circuit |
BOILER VALVE VC6013 | A three-way dividing valve with an actuator, controlled by the SPDT - 3/4” signal |
BOILER VALVE SPST | A three-way dividing valve with an actuator, controlled by the SPST - 3/4” signal |
You might also like