HPM2.C - Heat pump system consisting of the external unit HPMO2 and the internal 3in1 type HPMD...
HPM2.Z
HPM2.Z - an integrated set consisting of the external unit HPMO2 and the internal unit HPMI2 for installation in new and modernized systems.
The HPM2.Z system includes:
- external unit HPMO2
- internal unit type HPMI2
Description
Sets
Additional equipment
Technical data
Download files
Product Details
Internal Unit HPMI2
Heating unit with weather control, equipped with a hydraulic group and an electric heating set
- quick installation, thanks to matched elements placed in a compact housing
- advanced control capabilities:
- weather control heating
- daily and weekly temperature regulation cycle in the room and domestic hot water
- control of 2 heating circuits + domestic hot water circuit
- electric heating set with automatic power modulation:
- **3/6 kW for HPMO2-8 and HPMO2-12
- ***3/6/9 kW for HPMO2-16/23
- hydraulic group:
- three-way dividing valve, which allows water heating in cooperation with the domestic hot water exchanger
- safety group - diaphragm vessel with a capacity of 12 l, safety valve, electronic pressure gauge, automatic air vent
- remote control via the internet using the C.MI2 module (additional equipment)
External Unit HPM2
The pump installation is easier thanks to the built-in hydraulic group. The devices included in it are essential for the correct operation of the installation. The hydraulic group contains:
- Energy class: A+++(35 °C)/A++ (55 °C)
- Refrigerant R32
- EVI injection system ensures high efficiency and water temperature up to 60°C
- Wide operating range at external air temperature from -25°C to +43°C
- Quiet device operation – sound pressure level at a distance of 1m: 41 to 51 dB(A) depending on the selected device power - Q2 coefficient
- Planar room cooling or cooperation with a fan coil + Frost protection
- Smooth power modulation ensures optimal operation depending on heating needs from 2.3 to 8.2kW (A7/W35)
Watch the video and learn about the KOSPEL heat pump heating system
HPM2.Z-8 | HPM2.Z-12 | HPM2.Z-16 |
---|---|---|
The heat pump system includes:
|
The heat pump system includes:
|
The heat pump system includes:
|
Product Code | Description |
C.MI2 | The C.MI2 internet module allows remote control of the heat pump via the internet using a computer, tablet, or smartphone. Control is done through a web browser, providing easy and intuitive operation, as well as access to all advanced device control functions. |
HP.FF | Vibration isolation stand (base) for the heat pump 600x190x200 (2 pieces in the set). |
WE-019/01 | Temperature sensor for the storage tank / buffer. |
WE-019/05 | Temperature sensor for the heating circuits. |
HP.HS.24 | 24V humidity switch to protect against moisture accumulation. |
Product Code | HPM2.Z-8 | HPM2.Z-12 | HPM2.Z-16 |
---|---|---|---|
Energy Efficiency Class | A+++ (35 °C) / A++ (55 °C) | A+++ (35 °C) / A++ (55 °C) | A+++ (35 °C) / A++ (55 °C) |
Maximum Heating Power of the Heat Pump (kW) | 5.8 (A-7/W35) 7.1 (A+2/W35) 8.2 (A+7/W35) |
9.2 (A-7/W35) 11.3 (A+2/W35) 12.5 (A+7/W35) |
17.1 (A-7/W35) 20.5 (A+2/W35) 23.0 (A+7/W35) |
Efficiency Coefficient COP up to: | 4.6 (A+7/W35) 4.01 (A+2/W35) 3.49 (A-7/W35) |
4.75 (A+7/W35) 3.94 (A+2/W35) 3.37 (A-7/W35) |
4.76 (A+7/W35) 4.02 (A+2/W35) 3.47 (A-7/W35) |
Sound Power Level dB (A) | 49 | 55 | 59 |
Max Sound Pressure Level dB(A) - Coeff. Q2 | 41 from a distance of 1 meter | 47 from a distance of 1 meter | 51 from a distance of 1 meter |
Power Supply | 400 V 3N~ / 230 V~ | 400 V 3N~ / 230 V~ | 400 V 3N~~ |
Max Coolant Temperature | 60oC | 60oC | 60oC |
Nominal Current of the Overcurrent Circuit Breaker | 3x16A / 40A | 3 x 25 A / 50 A | 3 x 32A |
Min. Cross-Section of the Supply Cable | 5 x 2.5 mm2 / 3x6 mm2 | 5 x 2.5 mm2 / 3x6 mm2 | 5 x 2.5 mm2 |
You might also like
HPM2.P - integrated set consisting of an external unit HPMO2, an internal unit HPMI2 for...
HPM2.V - integrated set consisting of an external unit HPMO2, internal unit HPMI2 for...