• Out-of-Stock
HPM2.P

HPM2.P

HPM2.P - integrated set consisting of an external unit HPMO2, an internal unit HPMI2 for installation in new and modernized installations, a central heating buffer SVK, and a domestic hot water heat exchanger SWPC, providing hot water even for 7 people.

The HPM2.P system includes:

  • external unit HPMO2
  • internal unit of type HPMI2
  • central heating buffer SVK
  • domestic hot water heat exchanger SWPC
Kospel
Description

HPMI2 Internal Unit

Central heating unit with weather control, equipped with a hydraulic group and an electric heating assembly

  • Quick installation thanks to compact housing with fitted components
  • Advanced control capabilities:
    • Weather control of heating
    • Daily and weekly temperature regulation cycles in rooms and hot water
    • Control of 2 heating circuits + hot water circuit
  • Electric heating assembly with automatic power modulation:
    • **3/6 kW for HPMO2-8 and HPMO2-12
    • ***3/6/9 kW for HPMO2-16/23
  • Hydraulic group:
    • Three-way diverter valve that allows water heating in cooperation with the hot water exchanger
    • Safety group - 12-liter expansion vessel, safety valve, electronic pressure gauge, automatic air vent
  • Remote control via the internet using the C.MI2 module (additional equipment).

HPM2 External Unit

Pump installation is easier thanks to the built-in hydraulic group. The devices included in it are necessary for the correct operation of the installation. The hydraulic group includes:

  • Energy class: A+++(35 °C)/A++ (55 °C)
  • Coolant: R32
  • EVI injection system ensures high work efficiency and water temperature up to 60°C
  • Wide operating range at an external air temperature from -25°C to +43°C
  • Quiet operation of the device - acoustic pressure level at a distance of 1m: 52 to 56 dB(A) depending on the selected device power - coefficient Q2
  • Flat space heating or cooperation with a fan coil unit + Protection against freezing of condensate
  • Smooth power modulation ensures optimal operation depending on heating needs from 2.3 to 8.2 kW (A7/W35)

SVK Central Heating Buffer

  • Capacity: 104 liters
  • Energy class A - very good thermal insulation (PUR foam 65mm)
  • Accumulates heat in heating mode and cold in cooling mode
  • Extends the reliable operation time of the compressor by limiting the number of starts during transitional periods: spring - autumn
  • Supports the "defrost" function of the compressor without drawing energy from the heating circuits
  • Ensures optimal system operation by separating the hydraulic pump circuit from the heating circuits

SWPC Domestic Hot Water Heat Exchanger

Heat exchanger with the largest heating surface

  • Capacity: 300 liters, optimal for a 5-7 person family
  • Special design with two coils connected to a collector ensures a large flow and a heating surface of 4.22 m2. This guarantees the highest pump efficiency.
  • Possibility of connecting 1 or 2 additional electric heaters

Watch the video and learn about the Kospel heat pump heating system

Sets
HPM2.P-8HPM2.P-12HPM2.P-16
Heat pump system includes:
  • HPMO2-8 external unit
  • HPMI2 internal unit
  • SVK central heating buffer
  • SWPC domestic hot water heat exchanger
Heat pump system includes:
  • HPMO2-12 external unit
  • HPMI2 internal unit
  • SVK central heating buffer
  • SWPC domestic hot water heat exchanger
Heat pump system includes:
  • HPMO2-16 external unit
  • HPMI2 internal unit
  • SVK central heating buffer
  • SWPC domestic hot water heat exchanger
Optimal amount of domestic hot water for 5-7 persons. Optimal amount of domestic hot water for 5-7 persons. Optimal amount of domestic hot water for 5-7 persons.
Technical data
Product CodeHPM2.C-8HPM2.C-12HPM2.C-16
Energy Efficiency Class A+++ (35 °C) / A++ (55 °C) A+++ (35 °C) / A++ (55 °C) A+++ (35 °C) / A++ (55 °C)
Maximum Heat Pump Power (kW) 5.8 (A-7/W35)
7.1 (A+2/W35)
8.2 (A+7/W35)
9.2 (A-7/W35)
11.3 (A+2/W35)
12.5 (A+7/W35)
17.1 (A-7/W35)
20.5 (A+2/W35)
23.0 (A+7/W35)
Efficiency COP to: 4.6 (A+7/W35)
4.01 (A+2/W35)
3.49 (A-7/W35)
4.75 (A+7/W35)
3.94 (A+2/W35)
3.37 (A-7/W35)
4.76 (A+7/W35)
4.02 (A+2/W35)
3.47 (A-7/W35)
Sound Power Level dB (A) 60 63 64
Max Acoustic Pressure Level dB(A) - Q2 coefficient 52 55 56
Power Supply 400 V 3N~ / 230 V~ 400 V 3N~ / 230 V~ 400 V 3N~~
Max Heat Carrier Temperature 60oC 60oC 60oC
Nominal Overcurrent Protection Current 3x16A / 40A 3 x 25 A / 50 A 3 x 32A
Min. Power Cable Cross-Section 5 x 2.5 mm2 / 3x6 mm2 5 x 2.5 mm2 / 3x6 mm2 5 x 2.5 mm2
Total Heat Exchanger Capacity 305 305 305
Heat Exchange Surface Area (m2) 4.22 4.22 4.22
Coil Power (kW) 120 / 36 120 / 36 120 / 36
Insulation Thickness (mm) 67 67 67
Insulation Material PUR PUR PUR
Possibility of Using Heater
Buffer Tank Capacity (L) 60 60 60
Buffer Tank Insulation Thickness (mm) 65 65 65
Additional equipment
Product Code Description
C.MI2 The C.MI2 internet module allows remote control of the heat pump via the internet using a computer, tablet, or smartphone. Control is done through a web browser, providing easy and intuitive operation, as well as access to all advanced device control functions.
HP.FF Vibration isolation stand (base) for the heat pump 600x190x200 (2 pieces in the set).
WE-019/01 Temperature sensor for the storage tank / buffer.
WE-019/05 Temperature sensor for the heating circuits.
HP.HS.24 24V humidity switch to protect against moisture accumulation.
Download Promo folder

Download
Product Details

You might also like